LV main and sub-switchboards

The main switchboard is where your building or plant receives its low-voltage supply and distributes it to every downstream board. We build main switchboards (MSB) and sub-switchboards (SSB) to your single-line diagram, load schedule and consultant's specification.

Typical applications

  • Factories and process plants
  • Commercial buildings, offices and malls
  • Hospitals, schools and public buildings
  • Infrastructure and utility supply points

Engineering and customisation options

  • Incoming air circuit breaker (ACB) or moulded case circuit breaker (MCCB)
  • Digital power meters, protection relays and indication
  • Outgoing feeder arrangement to suit your load schedule
  • Top or bottom cable entry
  • Floor-standing layouts sized for your switch room
  • Powder-coat colour to your specification
  • Indoor or weatherproof designs to suit the installation site
  • A choice of forms of separation (Form segregation ratings) to your specification

Standards and certification

ASTA type certificates for 2000A, 3200A and 4000A assemblies to IEC 61439-2, and approved on the JKR EMAL list, Kategori III.

See our certifications and registrations

Lead time, warranty and brands

Typical lead time
4 to 8 weeks, depending on complexity
Warranty
1 year on new switchboards
Breaker and meter brands
Schneider Electric, LS Electric, ABB, Terasaki, Chint, Himel, Shihlin
Factory acceptance test
You are welcome to witness it, or to visit our factory

How it is built and tested

  1. Design and drawings. We review your single-line diagram and specification, then issue general arrangement and wiring drawings for approval.
  2. Sheet metal fabrication. Enclosures are laser-cut, sheared and bent in-house, so we control dimensions and lead time.
  3. Powder coating. Enclosures are powder coated in our own spray booth for a durable, even finish.
  4. Assembly and wiring. Busbars, breakers, metering and control wiring are assembled to the approved drawings.
  5. Testing and inspection. Boards are inspected and tested before they leave the factory, then commissioned on site.
Completed Kennek sub-switchboard with metering and outgoing compartments

What to send for a quotation

  • Single-line diagram (SLD) or schematic
  • Load schedule or list of outgoing circuits
  • Specification or consultant's requirements
  • Site location and installation conditions (indoor or outdoor)
  • Quantity and required delivery date
  • Preferred brands for breakers, meters and relays, if any
Request a quote

Send us your drawings for a quotation

Share your single-line diagram, specification or bill of quantities. We reply with a price and lead time within 5 working days, and small jobs are welcome.